PC5010 – Quick Arm / Quick Exit

Quick Arm

If the Quick Arm Enable option is enabled the panel can be armed by entering [✱][0]. This is a useful method of arming a Partition when someone without a User Code will be required to arm a Partition.

Note: The Quick Arm feature must be enabled in order for the Stay/Away function keys to operate as intended. If the feature is not enabled, the user will be required to enter their access code after pressing the Stay or Away function key in order to arm the system in the stay or away mode.

Quick Exit

Quick Exit will allow someone to leave an armed premise through a Delay type zone without having to disarm and rearm the system. When [✱][0] is entered, if the Quick Exit Enabled option is enabled, the panel will provide a two minute window to exit. During this time the panel will ignore the first activation of a Delay type zone. When the Delay zone is secured the panel will end the two minute time period. If a second Delay zone is tripped, or if the zone is not restored after two minutes, the panel will start entry delay.

The Quick Exit feature should not be used on Global Delay zones. If Quick Exit is used on a partitioned system, Keypad Blanking and Access Code Required to Remove Blanking should be enabled.

Installer Options
Code Required for Bypass ……………………………… Section [015], Option [5]
Master Code Not Changeable option ………………. Section [015], Option [6]
Quick Arm Enable ………………………………………….. Section [015], Option [4]
Quick Exit Enable …………………………………………… Section [015], Option [3]