VISTA 128BPT/250BPT: ULC Installation Requirements

  • The zone inputs of the control unit are considered Low Risk applications only.
  • The control unit must not be mounted on the exterior of a vault, safe or stockroom.
  • Subscriber control units capable of maintaining opening (disarming) and closing (arming) schedules must facilitate a hardcopy printout of the opening (disarming) and closing (arming) schedule programming and of all the programmed holidays.
  • Telephone service must be of the type that provides for timed release disconnect.
  • A server employed for control over network addressing, encryption or re-transmission, Must be designed to remain in the “on state” at all times.
  • Encryption must be enabled at all times for active communications channel security.
  • For ULC Installations, refer to CAN/ULC-S302, Installation and Classification of Burglar Alarm Systems for Financial and Commercial Premises, Safes and Vaults; CAN/ULC-S301, Standard for Central and Monitoring Station Burglar Alarm systems and CSA 22.1, Canadian Electrical Code, Part I, Safety Standard for Electrical Installations.