To perform a “quick exit” on a DSC PowerSeries Neo system, you must first be in “stay” mode, then press and hold the “Quick Exit” key for two seconds or press * then 0. This will give you a two-minute window to open a delay door and leave the premises. The system will re-arm automatically after the door is closed and the exit timer is canceled.
On an LCD keypad
- Press and hold the “Quick Exit” key for two seconds, or Press
*and0. The keypad will display “Quick Exit in Progress”. - Exit the premises through a designated delay door.
- Close the door. The system will fully re-arm automatically.
On a touchscreen
- Ensure the system is in “stay” mode.
- Press the dedicated “Quick Exit” key on the touchscreen.
- Exit the premises through a designated delay door.
- Close the door to re-arm the system.
Enabling the feature
- If “Quick Exit” is not working, you may need to enable it in the programming menu.
- Enter programming: Press
*then8and enter the installer code. - Go to section 015: This is the programming section for arming shortcuts.
- Enable the “Quick Exit” and “Quick Arming” features by scrolling through the options and making sure they are turned on.
- Press
#to exit programming.