Quick Arm
If the Quick Arm Enable option is enabled the panel can be armed by entering [✱][0]. This is a useful method of arming a Partition when someone without a User Code will be required to arm a Partition.
Quick Exit
Quick Exit will allow someone to leave an armed premise through a Delay type zone without having to disarm and rearm the system. When [✱][0] is entered, if the Quick Exit Enabled option is enabled, the panel will provide a two minute window to exit. During this time the panel will ignore the first activation of a Delay type zone. When the Delay zone is secured the panel will end the two minute time period. If a second Delay zone is tripped, or if the zone is not restored after two minutes, the panel will start entry delay.
Installer Options
Code Required for Bypass ……………………………… Section [015], Option [5]
Master Code Not Changeable option ………………. Section [015], Option [6]
Quick Arm Enable ………………………………………….. Section [015], Option [4]
Quick Exit Enable …………………………………………… Section [015], Option [3]
Master Code Not Changeable option ………………. Section [015], Option [6]
Quick Arm Enable ………………………………………….. Section [015], Option [4]
Quick Exit Enable …………………………………………… Section [015], Option [3]