StarLink SLE-LTE: Terminal Descriptions
Configure all inputs and outputs using the Manage- ment Center screen (located at www.napconoc.com). Located at the bottom of the StarLink radio PC board, the 17 terminals are described as follows:
Configure all inputs and outputs using the Manage- ment Center screen (located at www.napconoc.com). Located at the bottom of the StarLink radio PC board, the 17 terminals are described as follows:
Changing the entry delay on a DSC PowerSeries Neo requires access to Installer Programming. Note that industry standards (CP-01) typically enforce a minimum of 30 seconds for entry delays to reduce false alarms.
On a Honeywell Vista, the “House Code” is a two-digit identifier used to allow the panel to communicate with bi-directional wireless devices (like the 5827BD or 5804BDV fobs). You must enable this through the system’s programming mode. Important Considerations
To address a Honeywell 6160 keypad on a VISTA-21iP system, you must configure the address on the keypad itself and then ensure that address is enabled in the control panel’s programming. Step 1: Set the Keypad Address Every keypad on a VISTA system must have a unique address between 16 and…
The 1100DH Series Wireless Receiver provides up to 32 wireless zones for XT30/XT50 Series panels. The 1100DHE features 128-bit AES encryption. The 1100DH Series provides two-way, supervised communication using 900 MHz frequency hopping spread spectrum technology. The 1100DH contains additional transmit and receive amplifiers to enable greater distances for 1100…
The master/slave selector switch is provided for preventing cross talk between infrared beams for multi-level alarm. From the top level, set the switches of both the Transmitter and the Receiver to Master -> Slave 1 -> Slave 2 -> Slave 3.
The Takeover Module allows Resideo PRO Series control panels to communicate with previously installed wireless sensors and modules that transmit on the following frequencies: 319.5MHz, 345MHz, 433.42 and 433.92MHz. Refer to the PROTAKEOVER Compatibility Chart (p/n 800-24626 or later). The module connects directly to the control panel and is powered…
PGP922 detects shattering glass. Like all glass-break sensors, the detector might not consistently detect cracks in glass, or bullets that break through or break out the glass. Glass-break sensors should always be backed up by interior protection. Areas to avoid: Enrolling the device Qolsys 4 PowerSeries Neo Mounting the device…
To disable the Qolsys IQ Panel 4 camera, you can either stop image uploads via the Alarm.com website (or your provider’s portal) by turning off the automation rules for “Panel Camera Image Uploads” or directly through the panel’s settings by swiping down, going to Settings > Advanced Settings, entering the…