• Qolsys IQ4: How to disable the panel tamper

    To disable a tamper on a Qolsys IQ4 panel, you can either physically resolve the issue by ensuring the panel cover is fully seated against the backplate (pressing the internal black button) or, if working on the panel often, disable the alert in settings via Settings > Advanced Settings >…

  • Qolsys IQ4: How to enable wellness page

    To enable the Wellness Page on your Qolsys IQ Panel 4, swipe down from the top, go to Settings > Advanced Settings, enter your Installer Code (default 1111), then navigate to Installation > Installer Settings and check the box for Wellness Page, ensuring no partitions are enabled and the Check-In/Check-Out…

  • Qolsys IQ4: Wellness page

    The Wellness page is an optional page that if enabled by your dealer, allows quick and easy access to your emergency panic for more robust senior care installations. This page replaces the Security and Arming page as your default, home page to simplify use and access to help. The check…

  • PGPx303: Installation guide

    The PGPx303 is a thin, ultra-long-life PowerG magnetic contact device that is compatible with Johnson Controls’ PowerG control panels. The PGPx303 includes a built-in reed switch that opens when the magnet is removed from the contact. The device has the following features: Enrolling the device The following steps are relevant…

  • XF6: Terminals 17-28

    Zones 1 to 6 (Terminals 17 to 28) on the panel are 24 VDC powered zones. For programming purposes, the zone numbers are 1 through 6. Do not mix detectors from different manufacturers on the same zone. When wiring powered zones for 2-wire smoke detectors, refer to the following specifications:…

  • XF6: Standby battery selection

    To choose the type and number of batteries needed for 24 hours of standby power based on the Amp Hours Required calculation, perform the following: For listed installations, batteries can be installed in a DMP Model 349, 350 or 352S enclosure and all wiring shall run through conduit. The enclosure…

  • PROA7: System operation

    PROWLTOUCH Touchscreen Displays and OperationThe PROWLTOUCH touchscreen duplicates the functions of the Control Panel and mirrors its displays. Master User OptionsSelecting the Menu icon on the PROWLTOUCH Home Screen display the User options list. The options and operationsduplicate those of the Control Panel and provide access to the Installer and…

  • Legend 100: System operation

    AC INDICATOR This light indicates that AC power is connected to the Security System. Battery backup exists to operate the system in the event of a power failure. ARM/DISARM INDICATOR This light indicates whether the system is currently ARMED (ON) or DISARMED (OFF). In addition to this constant visual indication,…

  • OPTEX Beams: Terminal connections

    Do not exceed the voltage or current rating specified for any of the terminals during installation, doing so may cause fire or damage to the devices.