• Neo: Wireless supervision time

    Each wireless device (excluding wireless keys) sends a supervisory signal periodically. If the receiver does not receive a signal in the time programmed for the Supervision Time, it generates a supervisory fault. To program the wireless supervisory window complete the following steps.

  • Neo: Enrolling Wireless Devices

    1. Enter Installer Programming section [803][000]. 2. When prompted, either activate the device to enroll immediately or enter a device ID number. 3. The system control panel determines the type of device being enrolled and presents the appropriate programming options. 4. Use the scroll keys or enter the corresponding number…

  • Neo: Programming the HSM2164RF

    Enrolling the HSM2164RF receiver Enter Installer’s Programming section [902] then [000] to auto-enroll the HSM2164RF. The HSM2164RF module is enrolled automatically if it is connected to the Neo panel corbus terminals. The module count increases on the screen (example. M:01). The system detects a module supervisory trouble if it is…

  • 1132: Installation guide

    The 1132 is a wireless recessed contact that provides concealed protection for doors, windows, or any other application needing a discreet solution. As with all DMP 1100 Series transmitters, the onboard LED provides built‑in survey capability to allow for single‑person installations, eliminating the requirement for an external survey kit. The…

  • 1117: Installation guide

    The 1117 Wireless LED Annunciator provides a remote red LED for visual indication of system status. The 1117 can be programmed for nearly any panel output option and can respond to conditions such as armed area annunciation, ambush alarm, burglary alarm, exit timer, entry timer, schedules, or communication failure. PROGRAM…

  • DMP: Entering User Names

    Refer to the following when entering names information into the keypad.

  • Qolsys IQ4: Dealer Lockdown

    What is dealer lockdown? Dealer Lockdown is a feature that is introduced on software 4.6.1 where dealers lock devices to the current dealer on the panel; the device will not enroll on a panel with different Dealer Code. How to enable it? Settings > Advance Settings (Dealer Code) > Installations…

  • Qolsys IQ4: Silent Disarming

    Silent Disarming gives the option to the user to disarm the panel without causing any beeping sound at the panel or peripheral keypads. (Firmware version: 4.6.1) Silent Disarming Feature only allows the user to disarm the panel without making the beeping sound when it is armed in “Stay Mode”.

  • Ademco 5817: Setup guide

    The 5817 Multi-Point Universal Transmitter may have three contact loops connected to it. Each loop transmits a unique ID code to a 5800 wireless system receiver connected to the system control panel. The Primary Loop has several DIP switch selectable options that determine its connection requirements, response, and transmission characteristics…

  • Ademco 5819: Setup guide

    The ADEMCO 5819 Shock Processor Transmitter connects to inertia type shock detectors that are mounted externally to the transmitter case (detector not supplied), and is intended for use only with a wireless alarm system that supports 5800 Series wireless receivers. The 5819 has three unique zones. The first is for…