• SMP3 – Power Supply/Charger

    SMP3 power supply/charger converts low voltage AC input into 6VDC, 12VDC or 24VDC @ 2.5 amp of continuous supply current (see specifications). This general purpose power supply has a wide range of applications for access control, security and CCTV system accessories that require additional power. Installation Instructions: The SMP3 should…

  • 2GIG GC3: How to add sensor

    To add a wireless sensor to your 2GIG GC3 panel, you need to enter the system’s programming menu, select an available wireless zone, and “learn in” the new sensor’s serial number. Step 1: Access System Configuration Step 2: Program the Sensor Configure settings: Go through the remaining programming options on…

  • 2GIG: How to change the time

    To change the time on a 2GIG control panel, you will need to use the touchscreen interface to access the system’s toolbox settings. For 2GIG GC2 and Go!Control Panels These steps apply to models like the GC2 and original Go!Control panels: For 2GIG GC3 and Edge Panels These models have…

  • FMM-1 Monitor Module

    The FMM-1 Monitor Module is intended for use in intelligent, two-wire sys- tems, where the individual address of each module is selected using the built- in rotary switches. It provides either a 2-wire or 4-wire fault tolerant initiating device circuit (IDC) for normally open contact fire alarm and supervisory de-…

  • TG-1 Express: Multiple alarm format support

    The default program setting of the Telguard TG-1 Express is for Auto Detection of the panel alarm format. The Auto Format Detect feature allows the Telguard to adapt to receive any listed format on every alarm transmission. If the alarm format is changed for whatever reason, the Telguard will sense…

  • TG-1 Express: Panel-Supplied Power

    The Telguard TG-1 Express has an extremely low power profile, and as such can usually be powered from the panel to which it is connected. At 30mA (average consumption WHILE IDLE), the power required by the TG-1 Express is about the same as what is used by many keypads. Simply…

  • NOTIFIER N16: Gentex Notification Appliance

    Gentex Notification Appliance Using the ELRD-2.2K The Gentex Commander III Notification Appliance requires the ELRD-2.2K to be installed across the H+ and H- terminals on the appliance for proper operation on the N16 FACP. Refer to Figure 2.6, “Gentex Notification Appliance with ELRD-2.2K Wiring” for a wiring illustration. Follow the…

  • NOTIFIER N16: AC Power and Earth Ground Connection

    Primary power required for the FACP is 120 or 240 VAC, 50/60 Hz, 3.25 amps. The FACP will auto-detect the voltage used. No special switch or jumper is required to select AC power. Over- current protection for this circuit must comply with Article 760 of the National Electrical Code (NEC)…

  • NOTIFIER N16: Compatible Equipment

    Products marked with a check mark have not received UL 864 9th Edition certification and may only be used in retrofit applications. Devices: Licenses:

  • Neo: Wireless supervision time

    Each wireless device (excluding wireless keys) sends a supervisory signal periodically. If the receiver does not receive a signal in the time programmed for the Supervision Time, it generates a supervisory fault. To program the wireless supervisory window complete the following steps.