TG-1 Express: Multiple alarm format support

The default program setting of the Telguard TG-1 Express is for Auto Detection of the panel alarm format. The Auto Format Detect feature allows the Telguard to adapt to receive any listed format on every alarm transmission. If the alarm format is changed for whatever reason, the Telguard will sense the new format and accept the alarm signal.

Pulse Formats:

  • o 3+1 pulse; 10pps, Double Round,1400Hz ack
  • o 3+1 pulse; 20pps, Double Round,2300Hz ack
  • o 3+1 pulse; 40pps, Double Round,2300Hz ack
  • o 4+2 pulse; 20pps, Double Round,1400Hz ack
  • o 4+2 pulse; 20pps, Double Round,2300Hz ack
  • o 4+2 pulse; 40pps, Double Round,2300Hz ack
  • Contact ID
  • Modem IIe/IIIa2/4
  • SIA2 (SIA-DC-03 level 2 release at 300 baud)
  • DMP
  • Hexadecimal account numbers can be used with 3+1 or 4+2 formats, as well as Contact ID (4 or 10 digits) and Modem IIе/Шa/4 (4 digits).