PG9934: Installation manual

The PG9934(P)/PG8934(P)/PG4934(P) are 2-way wireless digital PIR/ Pet immune motion detectors with integrated cameras and microphones for alarm verification. The PGx934 Series distinguishes between human beings and pets weighing up to 38 kg (85lb) Target Specific Imaging™ and reduces false alarm by using True Motion Recognition™ Built-in link quality indicators reduce installation time by eliminating the need for the installer to physically approach the control panel.

Camera Features

  • Color or black & white images
  • Auto-setup for brightness and contrast via the control panel
  • Day and night CMOS camera, with IR illumination. This allows taking pictures in full darkness.
  • Camera range of 12m (40ft); with IR illumination 10m (33ft)
  • Camera operation modes:
  • Post alarm – pictures are taken after detection by detector.
  • Optional audio with images
  • Visual Verification

Notes:

  1. The camera and the listen-in feature are not to be enabled in UL listed product.
  2. The microphone is not to be enabled in a UL listed product.

Please be advised that this product may record and transmit photographic images and audio recordings in the event of an alarm condition, and that such images and recordings may be activated remotely by a monitoring company or other third party with authorized access to the system to which this device is connected. It is the responsibility of the party installing and/ or monitoring the product, and or the end user, to ensure that the installation, configuration and use of the product complies with applicable laws, including, without limitation, laws related to privacy, end user notifications and/or consent, posting of signage, and registration of the applicable system with local privacy authorities.

To the maximum extent permitted by applicable law, the manufacture disclaims, and shall be held harmless and indemnified by the purchaser of this product, for any and all liability related to compliance with such applicable laws by the installing party, monitoring company or any third party user of the product.

The product may be configured to limit the conditions under which the device will record, transmit or permit remote access to such photographic images and audio recordings.

Device setup

Caution! Risk of explosion if battery is replaced by an incorrect type. Observe polarity when installing batteries. Dispose of used batteries according to the manufacturer’s instructions and according to local rules and regulations. Batteries are to be replaced by service persons only. To be installed by service per- sons in non-hazardous locations only.

Note: To ensure the continued operation of all wireless devices after performing a system default, a global upload of all wireless programming via DLS is recommended before defaulting the system. After completing the system default, download the wireless programming.

Enroll the Device into the DSC system

  1. On a keypad press [*] [8] [Installer Code] [804] [000].
  2. Press and hold the device enroll button until the LED lights steady and then release the enroll button while the LED is still lit. A confirmation message then appears on the keypad.
  3. Press [*] key to confirm ID.
  4. Enter [3 digit zone #].
  5. Enter [3 digit zone type].
  6. Enter [1 digit partition #] for all desired partitions and press [#]. If using an LCD keypad you can scroll to the desired partitions and press [*] to toggle the partition.
  7. On an LCD keypad enter the label by using word library.

Enroll the Device into the Qolsys IQ4

  1. Access the Advanced Settings Menu:
    • From the main screen of your IQ4 panel, swipe down from the top center to reveal the quick settings tray.
    • Tap on Settings.
    • Select Advanced Settings.
    • The panel will prompt you for a code. Enter your system’s Installer Code (the default is often 1111 or 2222, but it might have been changed by your installer).
  2. Navigate to Device Installation:
    • Within the Advanced Settings menu, select Installation.
    • Next, tap on Devices.
    • Choose Security Sensors.
    • Finally, select Auto Learn Sensor. The panel will now enter an enrollment mode, actively listening for new PowerG devices.
  1. Activate the PG9934 Sensor:
    • The PG9934 is a motion detector, which means you need to trigger it to send an enrollment signal to the panel.
    • The easiest way to do this is to simply install the battery (if it’s not already in) or, if the battery is already in place, press and hold the internal enrollment button until the LED light turns solid yellow or orange, and then release it.
    • Be aware that for motion sensors exposed indoors, you might need to cover them initially to prevent them from constantly re-enrolling.