- Set up an account in the AlulaConnect portal.
- Add the MASTER CODE to the primary account user before connecting the BAT-Connect. This is required for the BAT-Connect to be able to properly configure the system settings.
- Disarm the system (all partitions).
- Enter panel programming mode using the installer code and program the following:
- Enable Communicator ([380]:[1])
- Enter a Telephone Number ([301])
- Enter Account Number ([310])
- Verify 1st Telephone Number is enabled in Call Direction Options ([351]-[376])
- Verify Master Code Not Changeable is Disabled ([015]:[6])
- Verify Access Code Required for *1, *2, *3 menus is disabled ([022]:[1])
- Verify that keypad lockout is either zero (disabled) or higher than 6 ([012])
- If you have removed any bus devices, perform a Module Supervision Reset ([902])
- Set Communicator Format to Contact ID ([350])
- Verify the panel is properly set up for Contact ID event reporting
- To enable reporting of the Period Test Transmission, program the “Periodic Test
Transmission” ([348]:[4]) and the “Periodic Test Transmission with Trouble” ([348]:[3]) reporting codes to “02”(optional)
- Exit programming mode and power down the DSC system.
- Connect the DSC system and the BAT-Connect as shown in the wiring diagram on the next page.
- Power up the DSC system.
- Verify proper operation and reporting of all event codes using your control panel’s installation manual.

- DSC control panels require connection to panel bus and Tip & Ring.
- Tip & Ring should not be wired to BAT-Connect using the same multi-conductor cable as the panel bus wiring. Tip & Ring should be in a separate cable.
- See below for supported DSC panels. If DSC panel is not listed, please contact Alula Support.