SIA CP-01 Quick Reference Chart

The minimum required system for SIA CP-01 is a VISTA-128BPTSIA Control, one of the following keypad models; 6160, TUXS, TUXW, 6280S, or 6280W and a UL Listed Bell.

Programming at installation may be subordinate to other UL requirements for the intended application.

Combined Entry Delay and Abort Window should not exceed 1 minute.

NOTES:

  • Using the Call Waiting Cancel feature on a non-Call Waiting line will prevent successful communication to the central station.
  • The control unit must be installed with a local sounding device and an off-premise transmission for Contact ID communication format.
  • Refer to the User Guide for procedures on Testing the System.
  • During Test mode, no alarm reports are sent to the central monitoring station.