To enable the visual exit countdown display on your Honeywell Vista 21iP, use an alpha keypad to enter programming mode via your Installer Code (default 4112) plus 800, press *197, enter a refresh rate from 1 to 5 seconds, and press *99 to save and exit.
Enable Exit Countdown Display
- Enter programming mode: type 4112 (Installer Code) + 800
- Access display field: type
*197 - Set refresh rate: enter a number from
1to5(this represents the number of seconds between display updates, e.g.,2refreshes every 2 seconds like 30, 28, 26…) - Exit programming mode: type
*99to save and return to normal operation
Enable Audible Exit Beeps (Optional)
If you also want beeping sounds during the countdown, make sure the audible exit warning is turned on:
- While in programming mode, press
*37 - Enter
1to enable the audible warning (or0to disable) - Press
*99to exit programming