DMP: Transfer Controller (XFER)

This option allows the transfer of all existing Z-Wave devices that are currently programmed in another manufacturer’s Z-Wave portable controller to your system.

This operation overwrites all Z-Wave devices that are programmed in your system. This option typically occurs at the time your DMP Z-Wave controller is installed.

Initiate the transfer at the other manufacturer’s Z-Wave portable controller after starting the transfer on the DMP keypad. Z-Wave devices are NOT overwritten until the transfer has been initiated at the other manufacturer’s Z-Wave portable controller. The transfer should not be stopped once the process has been initiated from the other manufacturer’s Z-Wave portable controller.

Transfer Operation:

  • 1. Access the User Menu.
  • 2. Press COMMAND until ZWAVE SETUP? displays.
  • 3. Press any select key or area. The keypad displays ADD LIST REMOVE.
  • 4. Press COMMAND again to display FAV XFER OPT. Select XFER. The keypad displays XFER WILL DELETE EXISTING DEVICES then displays XFER CNTRL SURE? YES NO.
  • 5. Select YES to to allow receipt of Z-Wave devices to your system. The keypad displays TRANSFERRING Z-WAVE DEVICES. Pressing the Back Arrow key cancels the transfer. Select NO to exit the XFER menu and return to ZWAVE SETUP?. All programming remains intact on the DMP Z-Wave controller and the transfer is cancelled.
  • 6. Initiate the transfer at the other manufacturer’s Z-Wave portable controller. All Z-Wave devices are added to the system with a default name (device type and number). A 16-character name may be assigned to the Z-Wave devices after the transfer is complete. When the transfer is complete the screen displays ZWAVE SETUP?.

Note: If TRANSMISSION FAILED displays on the screen, your system memory is cleared of all prior Z-Wave devices programming and each Z-Wave device must be added individually.