• Vista 128: Accessing another partition

    Each keypad is assigned a default partition for display purposes, and will show only that partition’s information. But, if the user is authorized, a keypad in one partition can be used to perform system functions in other partitions by using the GOTO command. Note that only those partitions authorized and…

  • Vista 128: Authority Levels

    Authority levels define the system functions a particular user can perform. Depending on the authority assigned to you, there are certain system functions you may be prohibited from performing. In summary, there are six authority levels, each having certain system restrictions as shown below. To view your authority level and…

  • DMP: Version 254 Update

    Updated Version 254 (9/17/25) firmware is now available for XR Series Control Panels. Panel Serial Number in Serial 3 Messages This update allows you to enable Serial 3 messages to include the panel serial number. If enabled, the panel family and corresponding serial number appear at the end of each…

  • Vista – Program function keys

    To program function keys on a Honeywell Vista alarm system using *57, enter program mode by typing the installer code (default 4112) followed by 800, then enter *57 to access function key programming. You will then be guided through prompts to assign functions to the unlabeled keys on the keypad,…

  • 5853: Installation Instructions

    General Information The 5853 Wireless Glassbreak detector with Transmitter senses the sound of breaking plate, tempered, laminated, wired, coated and sealed insulating glass. The self-contained detector includes a transmitter that can send alarms, tamper signals, and low battery messages to the control panel. The sensor is compatible with 5800-series wireless…

  • 4193SN: Installation Instructions

    The 4193SN is a serialized two-zone expander used to connect alarm sensing devices to controls which support serial number polling loop devices (i.e., Vista- 40, Vista-50P, and Vista-100). The 4193SN can be configured as one supervised zone (10K EOLR) and one unsupervised zone, or two unsupervised zones (normally closed devices…

  • SD-2000: Partition Assignment

    The SD-2000 Security system has the ability to be broken into separate independent sub systems known as partitions. Each user code can be valid in one or more partitions. Normally partition assignments are made by the installer through any of the programming methods during the initial system programming. This command…