• DMP: Common Keypad Displays

    Listed below are several keypad messages you may see on the display. Follow the instructions in the Possible Solutions column to correct the problem. In many cases, you need to call a service person to correct the problem. Displays that are not discussed here mean that your service representative should…

  • Vista: Testing the System

    The TEST key puts your system into Test mode, which allows each protection point to be checked for proper operation. The system will automatically exit the Test mode if there is no activity (no doors or windows are opened and closed, no motion detectors are activated, etc.) for 1 hour….

  • Vista128BPT: Using #70 Relay Menu Mode

    Your system may be set up so that certain lights or other devices can be turned on or off by using the #70 command from either a keypad or a telephone keypad (if 4286 VIP module is used). Ask your installer if this has been done in your system. To…

  • EL4XMTST: Instruction manual

    The Wheelock Eluxa weatherproof series EL4XMTST/EL3RMTST Multi-Tone Strobe appliances are designed for easy installation with a pre-wire capable EL4XBB surface box or EL3RMP mounting plate. Eluxa 4X/3R Multi-Tone Strobe is UL Listed for fire protection service under Standard 1971 for Signaling Devices for the Deaf and Hard of Hearing, UL1638…

  • NFS-640: Network Communications Module

    If networking two or more control panels or network control annunciators, each unit requires a Network Communications Module (NCM) or a High-Speed Network Communications Module (HS-NCM); wire and fiber versions of each are available. The wire and/or fiber versions of the NCM or the HS-NCM can be installed in any…

  • NFS-640: System Cabinets

    The control panel and modules are installed in a CAB-4 series backbox . There are four different sizes available, holding from one to four rows of equipment plus batteries (up to two 26 AH batteries). Backboxes are ordered separately from doors. The doors can be mounted on the left or…

  • NFS-640: Circuit Board Components

    The following two figures illustrate the location of the various connections, switches, jumpers and LEDs on the CPU2-640/CPU2-640E and its power supply. Figure 2.2 shows wiring connections; Figure 2.3 shows jumpers, LEDs and switches. See Section 3 “Installation” for larger images and more details. (Larger images are referenced on these…

  • 1116: Installation Guide

    The 1116 Wireless Relay Output provides a Form C (SPDT) dry relay contact rated for 1 Amp at 30 VDC. Regardless of the state of the relay, the 1116 operates on constant minimal standby current. The 1116 relay can be controlled from a DMP panel output programmed to respond to…

  • Vista – How to bypass a zone

    To bypass a zone on a Vista system, first enter in your Master Code. Then press the bypass number 6, followed by the zone number. The zone number will always be 2 digits on Vista-21 or lower. On Vista-128 and Vista-250 panels, the zone number will contain 3 digits. Example…

  • 401 USB Flash Module

    The Model 401 USB Flash Module allows you to easily field update firmware without the use of a computer and a Model 399 Programming Harness. The Model 401 is equipped with a standard USB 2.0 compatible Type A female connector for interface to a FAT32 USB Drive, a 4‑pin connector…