• DMP – 716 Output Expansion Module

    The 716 Output Expansion Module provides four independently programmable Form C (SPDT) relays and four zone‑following annunciator outputs for use on XR Series, XF6 Series, and XT75 Control Panels. Connect the 716 Module to the panel LX‑Bus. The 716 Module cannot be connected to the Keypad Bus. In addition to…

  • 712-8 Zone Expansion Module

    The Model 712‑8 Zone Expansion Module allows you to increase the number of protection zones available on a DMP panel. The 712‑8 provides a total of eight grounded zones. The zone expansion module provides a terminal strip for zone inputs, two 4‑pin headers for Keypad Bus or LX‑ Bus connections,…

  • XR Series – Add Wireless Receiver

    To add a DMP wireless receiver, connect it to the panel’s XBUS using the provided 4-wire harness, program a house code in the panel’s System Options to activate wireless operation, then briefly reset the panel to register the receiver. The 1100X Series Wireless Receiver provides up to 100 wireless zones…

  • ES200X – Remote Synchronization Output

    Synchronization is a feature that controls the activation of notification appliances in such a way that all devices will turn on and off at exactly the same time. This is particularly critical when activating strobes which must be synchronized to avoid random activation and a potential hazard to individuals. Devices…

  • ES200X – Class B NAC Wiring

    4 Class B Notification Appliance Circuits, supervised and power-limited – 4.7 kΩ, ½ watt P/N:71252 UL listed.

  • ES-200X – S-Tools Programming Utility

    The FS-Tools Programming Utility can be used to locally or remotely program the FACP from most Windows® compatible computers (PC), running Windows 7 or newer, 32 or 64 bit. The FACP program files can also be created and stored on the PC for future download to the con-trol panel. FS-Tools…

  • ES200X – Intelligent Addressable Modules

    Control Modules and Monitor Modules provide an interface between the control panel and conventional notification and initiating devices. Each module can be set to respond to an address with built-in rotary switches. The maximum address cannot exceed address 99. Note that a blinking LED on an addressable module indicates communication…

  • ES200X – Intelligent Addressable Detectors

    Intelligent, addressable detectors provide information to the control panel on an SLC Signaling Line Circuit This allows the control panel to continually process the information to determine the status (alarm, trouble, maintenance or normal) of each detector. Each detector responds to an SLC address that is set in the detector…

  • Program 5834 on Vista

    To program a Honeywell Vista 20 keyfob, you must first enter installer programming by entering your installer code + 800. Next, go to the *58 menu, and learn the keyfob’s unique serial number by pressing and holding any button on the fob. Then, assign the fob’s loops to specific functions,…