• MaxiProx 5375: DIP Switch Settings

    The MaxiProx reader is a self contained proximity reader. The two piece polycarbonate enclosure h as an O-ring that seals the pieces together and a cable fitting that seals the cable entry. The water resistant unit is rated for outdoor use. The enclosure is designed to fit on a single…

  • DSC Maxsys – Bypassing Zones

    On a Maxsys system, the Bypass Zone feature can be used to disarm a troubled zone so that the system can be armed. To use this feature, follow these steps:

  • Vista: Keypad error codes

    Common Vista 21 keypad error codes include AC LOSS (no AC power), OPEN CIRCUIT (keypad not communicating with the panel), and various communication-related codes like bF or Check 103 (wireless/long-range radio trouble) or FC (phone line failure). To clear most errors, you need to address the underlying issue and then…

  • Vista: Enable a daily test

    To enable a daily test on a Honeywell Vista 21, enter the installer code followed by pound ((#)) 0 to program a daily periodic test report schedule. This will automatically send a test signal to the central monitoring station every 24 hours. For immediate testing, you can force a test…

  • Vista: How to change the time

    To change the time on a Honeywell Vista 21 system, enter your Master Code or Installer Code, then press #63. Press the * key to start editing, and use the keypad to enter the hour, minutes, and AM/PM, then the year, month, and day. Press * when you are finished…

  • Brivo system requirements

    Brivo system requirements include an Ethernet network connection with outbound HTTPS (port 443) enabled on the firewall, minimum bandwidth (Cable/DSL compatible), and CAT5 or higher cabling with RJ45 connectors. For door stations, a PoE switch with internet access and specific cable types like Cat6 and OSDP reader cable are needed….

  • DMP X1 system requirements

    The DMP X1 system’s requirements are primarily based on its physical installation and power, as it is an access control hardware system, not a computer-based one. Key requirements include a power source between 12-24V AC or DC, a suitable enclosure for mounting, and a network connection (Ethernet, Wi-Fi, or optional…

  • Honeywell camera network requirements

    Honeywell camera network requirements include a stable internet connection with sufficient upload speed (e.g., 768 Kbps for AlarmNet or 2 Mbps for IPCAM-WOC1 per camera), meeting IEEE 802.3af PoE standards if using PoE, and a trusted, secure network with firewall protection. For wireless cameras, a router with WPS is required,…

  • Alarm.com doorbell network requirements

    Alarm.com doorbell cameras require an internet upload speed of at least 2 Mbps, and for the latest models, at least 2.5 Mbps upload speed. They need a Wi-Fi signal strength of at least 66% or higher, a router broadcasting an 802.11b/g/n 2.4 GHz network (some models support 5 GHz), and…